Refurbished: Please call for pricing.
|
B Braun Vista
- Dimensions: 5.5"W x 9.4"H x 7.8"D
- Battery:- 7.2V, 1.2Ah NiCad rechargeable
- Battery Operating Time: 3.5 hours at max delivery rate
- Rate Range:0.1-800 ml/hr in 0.1 ml increments with Vista™ tubing
- Volume to be Infused:0.1-9999.9 ml
- Occlusion Pressure: Variable Settings: Low - 8 PSI, High - 17 PSI
- KVO Rate: 1 ml/hr or selected rate whichever is lower
- Flow Rate Accuracy: ±5%
Mode/Features:
- Continuous and Piggyback Modes
- Program Mode for variable infusions
- Ramp/Taper Mode for TPN infusions
- Delay A Mode for postponing start and finish
|
Refurbished: Please call for pricing.
|
Graseby 3400
- Wide infusion rate range: 0.1-1200 ml/hr
- Multiple unit selection: ml/hr, ug/hr, mg/hr, ug/kg/hr, mg/kg/hr, ug/kg/mn, mg/kg/mn
- Syringe size flexibility: 5ml, 10ml, 20ml, 30ml, 50/60ml
- Simple operation: Menu driven display
- Cost effective: No dedicated disposables
- AC or battery operated (internal rechargeable battery)
- Accurate: +/- 2%
|
Refurbished: Please call for pricing.
|
Baxter AS50
- Configurable Drug Library
- Syringe Plunger Detection
- Backlight Display
- Adjustable Occlusion Specialty
- Selectable Modes of Delivery
- Accepts Syringe Sizes from 1-60cc
- Battery Voltage Indicator
- Adjustable "Near End" Alert
- RS232 Communication Port
|
Refurbished: Please call for pricing.
|
Baxter Infus O.R.
- Modify dose without multiple reprogramming steps.
- Adjust settings easily at any time during infusion.
- Change dial settings with a single hand for an immediate response.
- Save calculation time.
- Minimize risk of calculation error.
- Change Infusion Parameters/Rates with SMART LABELS
- SMART LABELS are magnetically coded/drug specific.
- Select from the available SMART Label library.
- Ideal for administering drugs requiring multiple dosage adjustments.
SPECIFICATIONS:
- Syringes - Monoject® or B-D®; Monoject® or B-D® 20 cc
- Accuracy – Infusion: linear rate ±3%. Bolus: linear displacement ±3%.
- Battery Life – Typical Use: 150 hours; at low battery and typical use: 4 hours
- Flow Rates – 0-600 mL/hr
- Flow Profile – Bolus: Continuous; Infusion: Pulsed Intermittently
- Occlusion Force – 8 ± 1 lb.
- Maximum Occlusion Pressure – 11 psi with 60 cc syringe; 20 psi with 20 cc syringe
- Occlusion Detection Time – 120 seconds at 36 mL/hr (inverse related to flow rate)
- Volume Stored on Occlusion – 1.1 mL (approx.)
- Back Pressure Effect on Accuracy – None to Occlusion Pressure
|
Refurbished: Please call for pricing.
|
Smith's Medfusion 3500
- FlowSentry™ : enhanced pressure trending for earlier clinical intervention
- Extensive delivery mode combinations including ml/hr, body weight, mass, volume over time, custom dilution and intermittent, loading dose, bolus dose, standby, volume limit and KVO rate
- Syringe sizes: accepts seven different manufactures syringe types, all manufacture’s syringe administration sets
- +/- 2% instrument accuracy: automatic syringe size detection
- Ergonomic, easy to use, horizontal design protects entire syringe barrel and allows single-handed loading
- MRI indicated: for MRI rooms mounted outside the 150 Gauss line and with shielded magnets of field strength of 1.5 Tesla or less.
- Mounts easily to an IV pole, an infant’s isolet or radiant warmer and rotation capabilities
- Bio-Med log-on line to set PM dates, view service history, and for access to calibration and diagnostic testing
- Internal battery capacity 10 hours at 5.0 ml/hr with 60ml syringe
- Wide- ranging flow rates and the capacity to infuse at low flow rates with larger syringes
|
Refurbished: Please call for pricing.
|
Baxter AS40
- Rate Parameters: 0.001 - 360 ml/hr, syringe-dependent
- Syringe Sizes: BD 1, 3, 5, 10, 20, 30, 60 ml. Monoject 1, 3, 6, 12, 20, 35, 60 ml. Terumo 1, 3, 5, 10, 20, 30, 60
- Volume limit: Full syringe can be delivered
- Battery capacity: 12 hours of operation at 2 ml/hr using 60 ml syringe, following a 16-hour charge
- Bottom LCD-Total volume delivered
- Accuracy: ± 3 %, not including syringe tolerance
|